    I’ve heard electric kettles are slower here because of the limits of our electrical system. I do have a kettle for the stove, though. I also rarely drink tea.

    • sushibowl@feddit.nl
      link
      fedilink
      arrow-up
      0
      ·
      21 days ago

      That’s true, because you use a 110V based system you have less power available to the kettle. It’s still a lot faster than an electric stove though. Not faster than an induction stove, probably.

      • dirtbiker509@lemm.ee
        link
        fedilink
        arrow-up
        0
        ·
        21 days ago

        We have a 2 phase, 120v or 240v. Standard wall outlets only have 1 phase at 120v and a 15amp limit.

        • hovercat@lemmy.blahaj.zone
          link
          fedilink
          English
          arrow-up
          0
          ·
          20 days ago

          Residential service is a single split 240v phase off of a 480V 3-phase line, while something like an apartment is 2 phase 208Y, with a single phase is 120V.

          • Revan343@lemmy.ca
            link
            fedilink
            arrow-up
            0
            ·
            19 days ago

            2 phase 208Y

            3 phase 208. But I imagine you know that, and just fat fingered the wrong key

            • hovercat@lemmy.blahaj.zone
              link
              fedilink
              English
              arrow-up
              0
              ·
              19 days ago

              Ah, I guess I meant that you’re getting 2 of the 3 phases, which is 208V phase-to-phase, or 120V phase to neutral.

    • jdeath@lemm.ee
      link
      fedilink
      arrow-up
      0
      ·
      21 days ago

      my electric kettle takes maybe 20 seconds to get to boiling water here in the USA

    • nixcamic@lemmy.world
      link
      fedilink
      arrow-up
      0
      ·
      21 days ago

      My friends just put a euro style 220 outlet on their counter and ordered a kettle online. Since they were building the house new it was basically no different than buying a 110v kettle.

        • Revan343@lemmy.ca
          link
          fedilink
          arrow-up
          0
          ·
          20 days ago

          American wiring is center-tapped ~240V; typical 120V outlets are from line on either side of the tap to the neutral, while dryers, stoves, etc. are 240V line to line. So they would have wired it like a stove, but then put in a euro style plug instead of a stove plug

        • nixcamic@lemmy.world
          link
          fedilink
          arrow-up
          0
          ·
          edit-2
          21 days ago

          You just run 220 from the panel to it. Almost every US house has 220 outlets for the dryer and stove anyhow. All you’re doing is using a different shaped plug, and like, wires are wires, they fit into a euro plug the same as they fit into a NEMA plug.

        • socsa@piefed.social
          link
          fedilink
          English
          arrow-up
          0
          ·
          21 days ago

          Technically it wouldn’t be to us code. It would be way smarter to just install a NEMA outlet and use an adapter, or even better just replace the plug on the kettle.

    • dan@upvote.au
      link
      fedilink
      arrow-up
      0
      ·
      20 days ago

      Standard outlets in the USA are 120v at 15A (1800W max peak, 1440W max continuous). In comparison, standard UK outlets are 230v at 13A (2990W peak)

      This also affects other things. For example, standard electric heaters (resistive heat) can’t get as hot in the USA.

      • Ross_audio@lemmy.world
        link
        fedilink
        arrow-up
        0
        ·
        20 days ago

        Due to a quirk of unifying 2 standards, Europe and the UK, the range is 216.2 volts to 253.0 volts.

        That encompasses infrastructure built to a tighter tolerance around 220V in Europe and infrastructure built to a tighter tolerance around 240V in the UK (and Australia).

        We expect 3150W out of a kettle most of the time. Our heaters will say 3kW.

        Usually you’ll find a few volts over 240 out of our outlets and that’s to design spec.